REMOTE MONITORING
Bullhorn RM4150S Remote Monitoring Unit
Bullhorn S Series RM4150S and RM4151S RMUs are cellular-based, reliable, two-way remote monitoring units that offer unrivaled protection against surges. They are ideal for rectifiers, tanks, and well casings. Bullhorn S Series RM4150S cellular, surge-hardened RMUs withstand the most extreme environments.
Why Choose Bullhorn RM4150S RMUs
Bullhorn S Series RMUs monitor your critical data points, including AC and DC volts, pipe-to-soil potential, shunts, instant off, and accumulators.
Insights that Improve Billing – Continuous access to electronic flow meter data means that you can always generate highly accurate reports that help improve invoicing. For example, you’ll be able to easily see when a customer is consuming more product than usual and make sure they’re being billed accordingly.
Remote Operations – Uploading measurements Bullhorn Web is automatic. Use the mobile application to change a configuration, take measurements, control interruption, and initiate instant off readings.
Reliable Interruption – Patented influence and interference technology and GPS synchronized interruption are available when you purchase or as a field upgrade.
Rugged Durability – Bullhorn remote monitors survive the harshest conditions with built-in surge protection. For enhanced safety against surge events, you can add a high-energy surge arrester or Advanced SurgeProtect Kit.
Accuracy – RM4150S and RM4151S RMUs enable you to find and fix minor issues before they become significant. They automatically calibrate and zero each measurement, and AC and DC voltage measurements are accurate within ±1 percent throughout the range. For example, a one mV (millivolt) measurement is accurate within ±10 microvolts.
Instant Alerts – Never worry about unknown problems with your unit. Configure text or email notifications that immediately inform you about high-priority situations, such as a low battery or unusually high consumption rates.
Integrated Compliance Solution – We provide a complete end-to-end system to prove regulatory compliance. Easily import Bullhorn’s field measurements into PCS™ Compliance software and integrate them into reports.
Unlimited Warranty – American Innovations’ industry-leading warranty covers your Bullhorn RMUs against any unexpected surge damage for up to three years.
Inputs
5 Analog Channels (RM4151S has 2 analog channels)
DC voltage range:
±150 V with accuracy of 1% of reading
AC voltage range:
150 V with accuracy of 1% of reading
Input impedance:
10 MΩ
Scan rate:
Once every 30 seconds
Channel-to-channelisolation:
≥ 250 V DC
Surge:
Survives multiple 30KV strikes.
Tested using 50uS waveform to
simulate lightning strike.
2 Digital Channels
Functions:
Digital input, accumulator, accumulator
reset, or contact closure (0 – 24 V DC)
Minimum logic:
1 = 2 V
Maximum logic:
0 = 1 V
Scan rate:
20 scans per second
Minimum pulse width:
250 ms
Interruption
Switch Out channel
Maximum current:
500 mA DC
Output voltage:
10-14 V DC
Minimum switching cycle:
1 s
On/off cycle increments:
100 ms
Interruption modes:
Daily, interference, start/stop,
continuous, and Instant Off
Interference mode:
Set up to 99 rectifiers or groups for influence studies
Relay types:
NO or NC, solid state or mechanical
Instant Off
Analog channel 3:
± 10 V DC, sampled 60 times per sec
IR drop edge delay:
0 to 60 seconds in increments of 1 ms
Configuration:
GPS-synchronized measurement using
configurable on, off, and delay settings
Communications
GSM cellular:
Worldwide compatibility on
LTE cellular networks
USA:
Carrier independent. Automatically selects
the best signal.
Poll, reconfigure, set alarm thresholds & update firmware over-the-air
Software Interface
Bullhorn Web
Bullhorn Tools for PC
Power Supply
AC:
100 – 240 V AC with included
AC/DC converter
DC:
10 – 14 V DC (9 – 36 V DC with
optional external DC/DC supply)
Backup:
Internal sealed rechargeable battery
Dimensions
RM4150S:
Polycarbonate enclosure
(5” x 2.25” x 8”)
External mount (optional):
Part #: 517200-000
Aluminum Enclosure
(7.3” x 4” x 12.4”)
Environment
Temperature:
-30° C to +70° C
Humidity:
0-95% non-condensing
Safety and Compliance
Emissions:
FCC Part 15